For time series scalar plots:

For time series scalar data:

Raw Data

When this option is selected, raw data will be supplied in the data products: no action is taken to modify the data. In general, all raw data is associated with a quality control (QAQC) flag. For time series scalar data (CSV, MAT files), these flags are stored adjacent to the data values. For plots, such as the time series scalar plot, data that fail quality control are marked on the plot with coloured data points and flag markers for emphasis.

This is the default option for plotting data products.

Clean Data

For time series scalar data (CSV, MAT), selecting this option will cause any data values with quality control failures (QAQC flags 3 and 4) to be replaced with NaNs. If the do not fill data gaps option is selected, data values with quality control failures will be removed. Because NaNs cannot be plotted, quality control failures will be excluded from any plots under the clean option. For all data products, when resampling with the clean option, any data with quality control failures are removed prior to the resampling (this rule applies to all resampling types: average, min/max, etc).

This is the default option for time series scalar data.